Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.32.3.5.(2) | Application | Intent |
OH1 | OS3 |
Objective | OH1 Indoor Conditions |
Attribution | |
Application | Application 1: Capacity of outdoor air supply fans installed to provide
outdoor air to self-contained heating-season mechanical ventilation systems
that are not coupled to forced air heating systems, serving single dwelling
units with 5 or fewer bedrooms that are supplied with electrical power
and a heating system, in buildings to which:
Exceptions:
except as stated in Sentence 9.32.3.1.(1), which applies to
heating-season mechanical ventilation systems designed to comply with CAN/CSA-F326-M.
|
Top of Page | |
Intent | Intent 1: To limit the probability that indoor air will not be replaced
at the same rate at which it is removed by a principal ventilation fan, which
could lead to excessive depressurization, which could lead to the spillage
of combustion products from fuel-burning appliances that are susceptible to
spillage, which could lead to negative effects on the air quality of indoor
spaces, which could lead to harm to persons. |