Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.32.3.5.(2)
OH1OS3
ObjectiveOH1 Indoor Conditions
Attribution
Application
Application 1: 
Capacity of outdoor air supply fans installed to provide outdoor air to self-contained heating-season mechanical ventilation systems that are not coupled to forced air heating systems, serving single dwelling units with 5 or fewer bedrooms that are supplied with electrical power and a heating system, in buildings to which:
  • Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], or
  • Part 6 applies [see Sentence 1.3.3.2.(1) of Division A for application of Part 6 and Sentence 6.2.2.1.(3)].
Exceptions: 
except as stated in Sentence 9.32.3.1.(1), which applies to heating-season mechanical ventilation systems designed to comply with CAN/CSA-F326-M.
Top of Page
Intent
Intent 1: 
To limit the probability that indoor air will not be replaced at the same rate at which it is removed by a principal ventilation fan, which could lead to excessive depressurization, which could lead to the spillage of combustion products from fuel-burning appliances that are susceptible to spillage, which could lead to negative effects on the air quality of indoor spaces, which could lead to harm to persons.