Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.32.3.6.(1) | Application | Intent |
OH1 | OS3 |
Objective | OS3 Safety in Use |
Attribution | |
Application | Application 1: Dwelling units that:
This applies to self-contained heating-season
mechanical ventilation systems serving single dwelling
units with 5 or fewer bedrooms that are supplied with electrical power
and a heating system, in buildings to which:
Exceptions:
except as stated in Sentence 9.32.3.1.(1), which applies to
heating-season mechanical ventilation systems designed to comply with CAN/CSA-F326-M.
|
Top of Page | |
Intent | Intent 1: In depressurization situations where air exhausting devices
operate without adequate replacement of indoor air with outdoor air, to limit
the probability of the spillage of carbon monoxide gas from fuel-burning appliances
that are susceptible to spillage, which could lead to the acute poisoning
or asphyxiation of persons. Intent 2: [Subclause (b)(i)] To expand the application of Articles 9.33.6.13. and 9.33.6.14. to
exhaust-only ventilation systems. |
Top of Page |