Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.32.3.7.(2)
+
Application
Application 1: 
Supplemental exhaust in kitchens where the only exhaust air intake for the principal ventilation fan is located in the kitchen.
This applies to self-contained heating-season mechanical ventilation systems serving single dwelling units with 5 or fewer bedrooms that are supplied with electrical power and a heating system, in buildings to which:
  • Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], or
  • Part 6 applies [see Sentence 1.3.3.2.(1) of Division A for application of Part 6 and Sentence 6.2.2.1.(3)].
Exceptions: 
except as stated in Sentence 9.32.3.1.(1), which applies to heating-season mechanical ventilation systems designed to comply with CAN/CSA-F326-M.
Top of Page
Intent
Intent 1: 
To exempt certain installations from the requirement to install a supplemental exhaust fan in the kitchen as stated in Sentence 9.32.3.7.(1), on the basis that the principal ventilation fan's single exhaust air intake, which is located in the kitchen, is likely to extract sufficient air from the kitchen to adequately remove vapours and pollutants produced by cooking.