This information has been archived because it is outdated and no longer relevant.
Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.32.3.8.(5) | Application | Intent |
OH1 | OS1 | OS3 |
Objective | OH1 Indoor Conditions |
Attribution | |
Application | Application 1: Supply fans rated to deliver outdoor makeup air, where
outdoor makeup air is not tempered upstream of the supply fan, in dwelling
units that:
This applies to self-contained heating-season
mechanical ventilation systems serving single dwelling
units with 5 or fewer bedrooms that are supplied with electrical power
and a heating system, in buildings to which:
Exceptions:
except as stated in:
|
Top of Page | |
Intent | Intent 1: To limit the probability of the premature failure of supply
fans, which could lead to excessive negative pressure. This
is to limit the probability of:
This is to limit the probability of negative effects on the air
quality of indoor spaces, which could lead to harm to persons.
Intent 2: To exempt supply fans from the requirement to be approved
to handle untempered outdoor air, in situations where the outdoor makeup air
is tempered before it reaches the supply fan. |
Top of Page |