Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.32.3.8.(6)
OS3
ObjectiveOS3 Safety in Use
Attribution
Application
Application 1: 
Installation of carbon monoxide alarming devices in each room containing a solid-fuel-burning appliance, in dwelling units that:
  • contain fuel-fired space- or water-heating appliances that are not direct-vented or mechanically vented [see Article 9.32.3.9. for additional CO alarm requirements], or
  • are located in an area where soil gas is deemed to be a problem but they do not incorporate a soil gas mitigation system.
This applies to self-contained heating-season mechanical ventilation systems serving single dwelling units with 5 or fewer bedrooms that are supplied with electrical power and a heating system, in buildings to which:
  • Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], or
  • Part 6 applies [see Sentence 1.3.3.2.(1) of Division A for application of Part 6 and Sentence 6.2.2.1.(3)].
Top of Page
Intent
Intent 1: 
To limit the probability that carbon monoxide gas entering living space in the rising plume of gases from a solid-fuel-burning appliance will go undetected, which could lead to the acute poisoning or asphyxiation of persons.