Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.32.3.8.(8) | Application | Intent |
+ |
Application | Application 1: Provision of makeup air in dwelling
units with solid-fuel-burning appliances,
where:
This applies to self-contained heating-season
mechanical ventilation systems serving single dwelling
units with 5 or fewer bedrooms that are supplied with electrical power
and a heating system, in buildings to which:
Exceptions:
except as stated in Sentence 9.32.3.1.(1), which applies to
heating-season mechanical ventilation systems designed to comply with CAN/CSA-F326-M.
|
Top of Page | |
Intent | Intent 1: To exempt certain dwelling units with solid-fuel-burning
appliances from the the requirement to provide makeup air [see Sentences 9.32.3.8.(1) to 9.32.3.8.(5)], in situations
where the spillage of combustion products from solid-fuel-burning appliances
is the sole likely adverse affect of depressurization and will be detected
by the carbon monoxide alarming devices required by Sentence 9.32.3.8.(6) and Article 9.32.3.9. |