Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.33.4.5.(2) | Application | Intent |
OS3 | OS1 |
Objective | OS1 Fire Safety |
Attribution | |
Application | Application 1: Anchorage of heating and air-conditioning equipment
with fuel or power connections serving only one dwelling
unit, in buildings to which Part 9 applies
[see Sentence 1.3.3.3.(1) of Division A for application of Part 9], in
locations where the spectral response acceleration, Sa(0.2), is
greater than 0.55. |
Top of Page | |
Intent | Intent 1: To limit the probability of an inadequate resistance to
seismic movement, which could lead to the overturning of heating and air-conditioning
equipment, which could lead to power lines breaking or gas or oil lines rupturing,
which could lead to fire, which could lead to harm to persons.
|
Top of Page |