Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.32.3.11.(3)
OH1OS2
ObjectiveOH1 Indoor Conditions
Attribution
Application
Application 1: 
Insulation of exhaust ducts that:
  • pass through an unheated space, or
  • are not separated from an unheated space by an insulated building assembly.
This applies to self-contained heating-season mechanical ventilation systems serving single dwelling units with 5 or fewer bedrooms that are supplied with electrical power and a heating system, in buildings to which:
  • Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], or
  • Part 6 applies [see Sentence 1.3.3.2.(1) of Division A for application of Part 6 and Sentence 6.2.2.1.(3)].
Exceptions: 
except as stated in Sentence 9.32.3.1.(1), which applies to heating-season mechanical ventilation systems designed to comply with CAN/CSA-F326-M.
Top of Page
Intent
Intent 1: 
To limit the probability that water vapour will condense on the interior surface of exhaust ducts, which could lead to:
  • the deterioration of ducts, which could lead to the blockage of ducts (e.g. ducts collapsing due to corrosion), which could lead to inadequate ventilation, or
  • the generation of pollutants from biological growth.
This is to limit the probability of negative effects on the air quality of indoor spaces, which could lead to harm to persons.