Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.23.1.1.(2)
+
Application
Application 1: 
Light constructions, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], where:
  • wall, floor and roof systems comprise lumber frames of small repetitive structural members or other engineered systems, and where
    • roof and wall planes are not clad, sheathed or braced on at least one side,
    • the small repetitive structural members are spaced more than 600 mm o.c.,
    • constructions resist horizontal loads imposed by soil,
    • the specified live load on supported subfloors and floor framing exceeds 2.4 kPa, or
    • the span of any structural member exceeds 12.20 m, and
  • wall, floor and roof systems are not made of lumber frames or other engineered systems of small repetitive structural members.
Top of Page
Intent
Intent 1: 
To expand the application of Part 4 to include wood-frame constructions that are beyond the application of Section 9.23.
Top of Page