Warning This information has been archived because it is outdated and no longer relevant.

Archived Content

Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

2.8.2.1.(1)
OP1OS1
ObjectiveOS1 Fire Safety
Attribution
(a)(i) [F11,F13-OS1.5]
(a)(ii) [F13-OS1.5,OS1.2]
(a)(iii) [F11-OS1.2,OS1.5]
(a)(iv) [F10-OS1.5]
(a)(v) [F02-OS1.2]
(b) to (d) [F12-OS1.2,OS1.5]
(e) [F10,F12-OS1.5]
(f) [F01-OS1.1]
(g) [F82-OS1.2,OS1.5]
Application
Application 1: 
Fire safety plans.
This applies to buildings or areas described in Article 2.8.1.1.:
  • buildings containing an assembly or a care or detention occupancy,
  • buildings required by the National Building Code of Canada to have a fire alarm system,
  • demolition and construction sites regulated under Section 5.6. of the NFC,
  • storage areas required to have a fire safety plan, as stated in Articles 3.2.2.5. and 3.3.2.9.,
  • areas where flammable liquids or combustible liquids are stored or handled, as stated in Article 4.1.5.5., and
  • areas where hazardous processes or operations occur, as stated in Article 5.1.5.1.
Application 2: 
This also applies to:
  • storage areas required to have a fire safety plan, as stated in Article 3.1.2.6. and 3.2.2.5.,
  • areas where flammable liquids or combustible liquids are stored or handled, as stated in Article 4.3.13.5.,
  • areas where hazardous processes or operations occur, as stated in Articles 5.2.3.7. and 5.5.3.1.,
  • tents and air-supported structures, as stated in Sentence 2.9.3.4.(2), and
  • covered malls, as stated in Sentence 2.12.1.1.(2).
Top of Page
Intent
Intent 1: 
To limit the probability that:
  • persons and emergency responders will not be notified of a fire emergency,
  • emergency responders will be delayed in carrying out their duties,
  • designated supervisory staff will not be appointed and organized to respond to fire emergencies,
  • occupants will not practise evacuation procedures, and
  • instructions, including schematic diagrams, describing the type, location and operation of building fire emergency systems will not be established.
This is to limit the probability of delays or ineffectiveness in conducting firefighting operations, evacuation or movement of persons to a safe place, which could lead to harm to persons, including emergency responders.
Intent 2: 
To limit the probability that:
  • fire hazards will not be controlled, and
  • building facilities, systems, equipment and devices will not be properly inspected or maintained.
This is to limit the probability of fire or the spread of fire, which could lead to harm to persons.
Top of Page