3.2.3.19.(3)

Objective

OP3 Protection of Adjacent Buildings from Fire

Attribution

Intent

Intent 1:

To supersede the requirements of Sentence 3.2.3.19.(2) and permit combustible heavy timber construction if certain conditions are met [not less than 50% of the area of any enclosing perimeter walls is open to the outdoors, and the walkways are at ground level]. These conditions are to limit the probability that:

  • fire will spread from one building to the adjacent building connected by means of the walkway, which could lead to damage to the connected building, and
  • emergency responders will be delayed or ineffective in carrying out fire suppression operations, which could lead to the spread of fire from one building to the adjacent building connected by means of the walkway, which could lead to damage to the connected building.