3.3.4.4.(6)

Objective

OS3 Safety in Use

Attribution

Intent

Intent 1:

To exempt egress facilities serving a dwelling unit from the requirements of Sentences 3.3.1.3.(8) and (9), and 3.3.1.9.(7) which would otherwise:

  • require a doorway to the exterior, a public corridor or an exterior passageway, or
  • prohibit a dead-end corridor that is longer than 6 m.

This is on the basis that there is a second means of egress from the dwelling unit available if the route through a means of egress leading to the exit is impeded, blocked, or untenable.

This is to limit the probability that persons will not have the choice of an alternative egress route in the case where one route is blocked or obstructed in an emergency situation, which could lead to delays in the evacuation or movement of persons to a safe place, which could lead to harm to persons.

Top of Page