5.8.1.1.(1)

Objective

OH1 Indoor Conditions

Attribution

[F60-OH1.1,OH1.2,OH1.3]Applies to portion of Code text: “… the bottom of every exterior foundation wall and every floor-on-ground shall be provided with drainage.”

Intent

Intent 1:

To limit the probability of excessive moisture loading on below-ground assemblies, which could lead to moisture ingress from the ground.

This is to limit the probability of:

  • the inadequate control of relative humidity or water accumulation,
  • the generation of pollutants from biological growth or from materials that become unstable on wetting, or
  • deterioration, which could lead to compromised integrity of environmental separators.

This is to limit the probability of:

  • negative effects on the air quality of indoor spaces,
  • the inadequate thermal comfort of persons, and
  • contact with moisture.

This is to limit the probability of harm to persons.

Top of Page