Intent 1:
To limit the probability of:
- ice lens formation beneath the foundations of regularly
occupied buildings, which could lead to the displacement of foundation
elements, or
- the displacement of relatively massive concrete steps
due to frost.
This is to limit the probability of
compromised structural integrity, which could lead to:
- structural failure,
- for environmental separators or elements supporting
an environmental separator, the displacement or failure of required
environmental separation elements, which could lead to the deterioration
of building elements, or
- an inability to resist expected loads, which could lead
to
- the excessive deformation or deflection of walls, or
- the excessive deflection or vibration of floors.
This is to limit the probability of:
- the space being unsuitable for its intended use, or
- damage to the building.