9.20.6.2.(1)

Objective

OS3 Safety in Use

Attribution

[F20,F22-OS3.1]Applies to floors and elements that support floors.

Intent

Intent 1:

To limit the probability of:

  • inadequate width of masonry units in loadbearing contact with each other, which could lead to an inability to resist expected gravity or lateral loads,
  • insufficient bond strength to resist tensile stresses in non-loadbearing masonry cavity walls, or
  • inadequate bonding of ties with mortar, which could lead to inadequate pullout and pushout resistance.

This is to limit the probability of:

  • compromised structural integrity of masonry construction,
  • where masonry construction is part of an environmental separator, the displacement or failure of required environmental separation elements, which could lead to deterioration,
  • in assemblies exposed to moisture or the exterior, damage and deterioration, or
  • an inability to resist expected loads, which could lead to excessive deflection or vibration of floors.

For floors and elements supporting floors, this is to limit the probability of persons losing their balance, tripping or falling, which could lead to harm to persons.