9.20.10.1.(2)

Objective

OH4 Vibration and Deflection Limitation

Attribution

(a) [F20,F22-OH4]Applies to floors and elements that support floors.

Intent

Intent 1:

To limit the probability of inadequate lateral support, which could lead to insufficient lateral stiffness, which could lead to an inability to resist lateral loads or inadequate distribution of gravity loads, which could lead to cracking or buckling.

This is to limit the probability of:

  • compromised structural integrity of masonry construction,
  • where masonry construction is part of an environmental separator, the displacement or failure of required environmental separation elements, which could lead to deterioration, or
  • in assemblies exposed to moisture or the exterior, damage and deterioration.

For floors and elements supporting floors, this is to limit the probability of excessive movement, deflection or vibration, which could lead to negative effects on the psychological well-being of persons.

Top of Page