9.22.7.2.(1)

Objective

OS1 Fire Safety

Attribution

Intent

Intent 1:

To limit the probability that an insufficient thickness of surrounding masonry will lead to an inability to dissipate excess heat conducted from the fire chamber, which could lead to the ignition of combustible building components, which could lead to harm to persons.