9.23.9.9.(3)

Objective

OS2 Structural Safety

Attribution

[F20,F22-OS2.3]Applies to elements that support or are part of an environmental separator.

Intent

Intent 1:

To limit the probability of:

  • inadequate leverage provided by the inboard portion of cantilevered joists,
  • inadequate resistance, by headers and fasteners, to upward reactions, or
  • inadequate fastening of the inboard portion of cantilevered joists.

This is to limit the probability of:

  • the excessive movement, deformation or failure of floor assemblies, or
  • the excessive deflection of the roof.

This is to limit the probability of compromised structural integrity, which could lead to:

  • the structural collapse of wood-frame construction, or
  • for exterior floors or floors supporting environmental separators, the excessive deformation, displacement or failure of required environmental separation elements, which could lead to deterioration, which could lead to further compromised structural integrity.

This is to limit the probability of harm to persons.