Intent 1:
To limit the probability that studs installed 'on
the flat' will not act compositely with the sheathing and will be
subject to excessive gravity and lateral loads, which could lead to
an inability to resist expected gravity and lateral loads.
This is to limit the probability of compromised structural
integrity, which could lead to:
- the structural collapse of wood-frame construction,
or
- where wood-frame construction supports or is part of
an environmental separator, the excessive deformation, displacement
or failure of required environmental separation elements, which could
lead to deterioration, which could lead to further compromised structural
integrity.
This is to limit the probability of:
- the space being unsuitable for its intended use,
- compromised operation of doors or windows, or
- damage to the building.