9.23.10.6.(3)

Objective

OP2 Structural Sufficiency of the Building

Attribution

(b) [F20-OP2.5]
(b)[F20,F22-OP2.3]Applies to elements that support or are part of an environmental separator.

Intent

Intent 1:

To limit the probability that studs will not provide adequate support to lintels or will not have adequate capacity to transfer loads, which could lead to studs or lintels being unable to resist expected gravity and lateral loads.

This is to limit the probability of compromised structural integrity, which could lead to:

  • the structural collapse of wood-frame construction, or
  • where wood-frame construction supports or is part of an environmental separator, the excessive deformation, displacement or failure of required environmental separation elements, which could lead to deterioration, which could lead to further compromised structural integrity.

This is to limit the probability of:

  • the space being unsuitable for its intended use,
  • compromised operation of doors or windows, or
  • damage to the building.

Top of Page