9.23.11.2.(2)

Objective

OP2 Structural Sufficiency of the Building

Attribution

Intent

Intent 1:

To limit the probability of inadequate bearing and fastening dimensions between walls and their supports, and eccentricity between load and support, which could lead to an inability to resist expected gravity and lateral loads, which could lead to:

  • the inadequate distribution of vertical loads to and from studs, which could lead to the excessive deflection of wall plates and walls, or
  • inadequate diaphragm action of plates, which could lead to the excessive deflection of walls.

This is to limit the probability of compromised structural integrity, which could lead to:

  • the structural collapse of wood-frame construction, or
  • where wood-frame construction supports or is part of an environmental separator, the excessive deformation, displacement or failure of required environmental separation elements, which could lead to deterioration, which could lead to further compromised structural integrity.

This is to limit the probability of:

  • the space being unsuitable for its intended use,
  • compromised operation of windows or doors, or
  • damage to the building.