9.24.1.4.(1)

Objective

OP2 Structural Sufficiency of the Building

Attribution

[F20,F22,F80-OP2.3]Applies to elements that support or are part of an environmental separator.

Intent

Intent 1:

To limit the probability that the performance and physical properties of steel screws, with respect to withdrawal resistance, pull-through resistance or shear strength, will fall significantly below expectations, which could lead to an inability to resist expected lateral and gravity loads.

This is to limit the probability of the excessive movement or deformation of walls, which could lead to:

  • the structural failure of walls, or
  • for exterior walls, the excessive deformation, displacement or failure of required environmental separation elements, which could lead to deterioration.

This is to limit the probability of:

  • the space being unsuitable for its intended use,
  • compromised operation of windows and doors, or
  • damage to the building.

Top of Page