9.25.4.1.(1)

Objective

OH1 Indoor Conditions

Attribution

Intent

Intent 1:

To limit the probability of an uncontrolled diffusion of water vapour from air in heated space into insulated wall, ceiling and floor assemblies.

This is to limit the probability of:

  • condensation, or
  • compromised thermal performance of components intended to provide resistance to heat transfer.

This is to limit the probability of:

  • an inadequate control of the temperature of interior spaces or relative humidity,
  • the generation of pollutants from biological growth or from materials that become unstable on wetting, or
  • deterioration, which could lead to compromised integrity of assemblies acting as environmental separators.

This is to limit the probability of:

  • negative effects on the air quality of indoor spaces, or
  • the inadequate thermal comfort of persons.

This is to limit the probability of harm to persons.