9.27.5.1.(6)

Objective

OH1 Indoor Conditions

Attribution

Intent

Intent 1:

To limit the probability of an insufficient length of overlap to permit the secure fastening of the top edges of asbestos-cement shingles, which could lead to inadequate anchorage for fasteners to resist gravity loads and lateral wind loads, which could lead to the displacement of cladding, the opening of joints or the failure of caulking, which could lead to:

  • precipitation or meltwater ingress, or
  • compromised thermal performance of components intended to provide resistance to heat transfer.

This is to limit the probability of:

  • an inadequate control of temperatures of interior spaces or relative humidity,
  • the generation of pollutants from biological growth or from materials that become unstable on wetting,
  • deterioration, which could lead to compromised integrity of exterior walls or elements protected by exterior walls, or
  • water accumulation in interior spaces.

This is to limit the probability of:

  • negative effects on the air quality of indoor spaces,
  • the inadequate thermal comfort of persons, and
  • contact with moisture.

This is to limit the probability of harm to persons.