9.27.8.1.(1)

Objective

OP2 Structural Sufficiency of the Building

Attribution

[F20-OP2.1,OP2.3,OP2.4][F22-OP2.3,OP2.4,OP2.5]Applies where panel-type cladding is installed to provide the required bracing.

Intent

Intent 1:

To limit the probability that the performance of plywood will fall significantly below expectations, which could lead to:

  • premature failure of plywood cladding, or
  • where panel-type siding is installed as bracing to satisfy Subclause 9.23.13.1.(2)(a)(i) and Clause 9.23.13.6.(1)(a), an inability to resist lateral loads, which could lead to racking of exterior walls.

This is to limit the probability of:

  • the deformation of the building, or
  • the displacement of cladding, trim and flashing, opening of joints or failure of caulking, which could lead to
    • precipitation or meltwater ingress, which could lead to deterioration, which could lead to compromised structural integrity of exterior walls or elements protected by exterior walls, or
    • falling cladding components.

This is to limit the probability of:

  • the space being unsuitable for its intended use,
  • compromised operation of windows and doors, or
  • damage to the building.

Top of Page