Intent 1:
To limit the probability of:
- inadequate density to resist water absorption,
- inadequate strength to resist gravity, lateral, impact
or abrasion loads, or
- inadequate resistance to freeze-thaw stresses.
This is to limit the probability of
the cracking of stucco, which could lead to:
- precipitation or meltwater ingress, which could lead
to deterioration, which could lead to the structural failure of exterior
walls or elements protected by exterior walls, or
- stucco detaching and falling from the building.
This is to limit the probability of harm to persons.