Intent 1:
To limit the probability that tiles:
- will absorb water from the mortar, which could lead
to inadequately strong mortar, or
- will not be completely embedded in the mortar, which
could lead to the inadequate adhesion of tiles to the substrate.
This is to limit the probability of
the dislodgement of tiles or the ingress of water behind tiles, which
could lead to compromised protection for moisture-vulnerable substrates,
which could lead to the deterioration of the substrate, which could
lead to the substrate being unable to resist expected impact, gravity
or lateral loads.
This is to limit the probability of the deformation or detachment
of interior finishes, which could lead to:
- where the substrate for the tile contributes to the
required bracing or lateral support for studs, the buckling or racking
of walls, which could lead to structural failure, or
- where the substrate for the tile serves as a required
environmental separation element, the excessive deformation, displacement
or failure of such elements, which could lead to further deterioration,
which could lead to further compromised structural integrity.
This is to limit the probability of harm to persons.