4.1.7.1.(5)

Objective

OP2 Structural Sufficiency of the Building

Attribution

Intent

Intent 1:

To limit the probability that the calculation of wind load on a building will not take into account the expected maximum winds at the site based on terrain roughness, the height of the surface or part thereof above ground, and hill configuration, which could lead to:

  • the excessive deformation of, or excessive stress in, structural elements, which could lead to damage to the building, or
  • the excessive deflection or excessive vibration of structural elements, which could impede the intended use and occupancy of the building.

Intent 2:

To limit the probability that the calculation of wind load used for the design will not take into account the height of the surface or part thereof and shielding provided by surrounding buildings or trees, which could lead to:

  • the excessive deformation of, or excessive stress in, structural elements, which could lead to damage to the building, or
  • the excessive deflection or excessive vibration of structural elements, which could impede the intended use and occupancy of the building.

Top of Page