To limit the probability of one Seismic Force Resisting System being supported by another Seismic Force Resisting System with a higher combined reduction factor, which could lead to a lower base shear, which could lead to structural failure, which could lead to harm to persons.
To direct Code users to Sentence 4.1.8.15.(5), which addresses design forces.