4.1.8.15.(1)

Objective

OS2 Structural Safety

Attribution

Intent

Intent 1:

To limit the probability that the design of a floor or roof acting as a diaphragm will not take into account the maximum expected seismic forces tributary to that storey which will be transferred through the diaphragm into the Seismic Force Resisting System, which could lead to structural failure, which could lead to harm to persons.

Intent 2:

To limit the probability that the openings in the diaphragm or the shape of the diaphragm will not be taken into account in its design for earthquake, which could lead to stress concentrations, which could lead to structural failure, which could lead to harm to persons.