4.1.8.16.(1)

Objective

OS2 Structural Safety

Attribution

[F20-OS2.1]Applies to portion of Code text: “Foundations shall be designed to resist the lateral load capacity of the SFRS…”

Intent

Intent 1:

To limit the probability that the capacity of the foundation to resist the maximum expected seismic forces will be less than the capacity of the superstructure, which could lead to a sudden brittle failure of the foundation, which could lead to the collapse of the building, which could lead to harm to persons.