5.1.4.1.(1)

Objective

OS1 Fire Safety

Attribution

(a) [F20,F51,F55-OS1.4]Applies where required life safety systems are incorporated in environmental separators.

Intent

Intent 1:

To limit the probability of an inadequate resistance to expected environmental loads and deterioration, which could lead to:

  • condensation,
  • precipitation ingress, or
  • moisture ingress from the ground.

Where required life safety systems are incorporated in environmental separators, this is to limit the probability of compromised operation of temperature-sensitive or moisture-sensitive life safety systems, which could lead to harm to persons.