5.5.1.1.(1)

Objective

OH1 Indoor Conditions

Attribution

Intent

Intent 1:

To limit the probability of

  • the inadequate control of vapour diffusion (except the diffusion of moisture from the ground) through environmental separators under expected environmental loads, or
  • the inadequate venting of vapour to the exterior.

This is to limit the probability of the accumulation of condensation, which could lead to:

  • the generation of pollutants from biological growth or from materials that become unstable on wetting, or
  • deterioration, which could lead to compromised integrity of environmental separators.

This is to limit the probability of:

  • negative effects on the air quality of indoor spaces, and
  • the inadequate thermal comfort of persons.

This is to limit the probability of harm to persons.