9.9.6.6.(2)

Objective

OS3 Safety in Use

Attribution

Intent

Intent 1:

To supersede the requirements in Sentence 9.9.6.6.(1), which prohibits exit doors to open directly onto a step, on the basis that a step of limited height will minimize the danger of door blockage from ice or snow without creating an undue risk of injury or delay.

This is to limit the probability that the accumulation of ice or snow outside the door will block the door, which could lead to persons being unable to leave the building in an emergency situation, which could lead to delays in the evacuation or movement of persons to a safe place, which could lead to harm to persons.

Top of Page