9.15.4.5.(3)

Objective

OS3 Safety in Use

Attribution

[F20,F22-OS3.1]Applies to floors and elements that support floors.

Intent

Intent 1:

To limit the probability of insufficient reinforcement or that reinforcement across a cold joint will not be adequately bonded to the concrete, which could lead to tension loads not being transferred to each side of the joint, which could lead to concrete cracking or the displacement of foundation walls.

This is to limit the probability of:

  • compromised structural integrity, or
  • where elements support or are part of an environmental separator, the displacement or failure of required environmental separation elements, which could lead to the deterioration of building elements.

For floors and elements supporting floors, this is to limit the probability of excessive deflection, which could lead to rough or uneven walking surfaces, which could lead to persons tripping or falling, which could lead to harm to persons.

Top of Page