9.20.17.6.(2)

Objective

OH1 Indoor Conditions

Attribution

Intent

Intent 1:

To limit the probability of the improper placement or insufficient embedment of anchor bolts, which could lead to anchor bolts pulling out, which could lead to the roof framing becoming detached from the insulating concrete form walls, which could lead to an inability to resist expected gravity and lateral loads.

Where elements support or are part of an environmental separator, this is to limit the probability of the excessive deformation, displacement or failure of required environmental separation elements, which could lead to:

  • condensation,
  • rainwater ingress,
  • the ingress of moisture, or
  • compromised thermal performance of components intended to provide resistance to heat transfer.

This is to limit the probability of:

  • an inadequate control of temperatures of interior spaces, relative humidity, or water accumulation,
  • the generation of pollutants from biological growth or from materials that become unstable on wetting, or
  • deterioration, which could lead to further compromised integrity of environmental separators.

This is to limit the probability of:

  • negative effects on the air quality of indoor spaces,
  • the inadequate thermal comfort of persons, and
  • contact with moisture.

This is to limit the probability of harm to persons.