9.32.3.13.(11)

Objective

OH1 Indoor Conditions

Attribution

Intent

Intent 1:

To limit the probability of excessive restriction of airflow through screens or grilles on air intake or exhaust openings, which could lead to:

  • where both exhaust and supply fans are restricted, inadequate ventilation,
  • where exhaust fans alone are restricted, excessive positive pressure, or
  • where supply fans alone are restricted, excessive negative pressure.

This is to limit the probability of:

  • the inadequate control of airborne pollutants or oxygen and other components necessary for breathable air,
  • the inadequate control of relative humidity, which could lead to condensation on interior surfaces,
  • condensation within assemblies,
  • moisture ingress from the ground,
  • the ingress of soil gases (such as methane and radon), or
  • the spillage of combustion products from fuel-burning appliances that are susceptible to spillage.

This is to limit the probability of:

  • the generation of pollutants from biological growth or from materials that become unstable on wetting, or
  • pollutant ingress (including combustion products and soil gases).

This is to limit the probability of negative effects on the air quality of indoor spaces, which could lead to harm to persons.

Top of Page