Intent 1:
To limit the probability that concrete block of
inadequate compressive strength will be used, which could lead to:
- an inadequate resistance to water absorption, which
could lead to excessive water absorption, which could lead to blocks
cracking due to freeze-thaw stresses, or
- an inability to support loads, which could lead to blocks
cracking.
Where elements support or are part
of an environmental separator, this is to limit the probability of
damage to the foundation and the superstructure, which could lead
to:
- condensation,
- rainwater ingress, or
- compromised thermal performance of components intended
to provide resistance to heat transfer.
This is to limit the probability of:
- an inadequate control of temperatures of interior spaces,
relative humidity, or water ingress and accumulation,
- the generation of pollutants from biological growth
or from materials that become unstable on wetting, or
- compromised integrity of the environmental separator,
which could lead to the deterioration of building elements.
This is to limit the probability of:
- negative effects on the air quality of indoor spaces,
- the inadequate thermal comfort of persons, and
- contact with moisture.
This is to limit the probability of harm to persons.