9.25.1.1.(2)

Objective

OS2 Structural Safety

Attribution

Intent

Intent 1:

To limit the probability of:

  • excessively low temperatures of interior surfaces or within wall, ceiling or floor assemblies, which could lead to condensation,
  • excessive air infiltration and exfiltration,
  • excessive airborne vapour transfer from interior above ground and exterior below ground,
  • precipitation ingress due to air pressure differences,
  • uncontrolled diffusion of water vapour from air in heated space into insulated wall, ceiling and floor assemblies, which could lead to condensation,
  • inadequate moisture diffusion, venting, or drainage of moisture to the exterior, which could lead to condensation, or
  • compromised thermal performance of components intended to provide resistance to heat transfer.

This is to limit the probability of condensation, which could lead to deterioration, which could lead to compromised structural integrity of assemblies acting as environmental separators, which could lead to harm to persons.

Top of Page