9.13.4.3.(2)

Objective

OH1 Indoor Conditions

Attribution

Intent

Intent 1:

To limit the probability that:

  • components of a future system for the remediation of high indoor radon concentration will be located inappropriately or be inaccessible for the future installation of exhaust equipment, which could lead to a very difficult and costly installation of connections to the gas-permeable layer,
  • the layer beneath the air barrier cannot be depressurized, or
  • the connections to a future system for the remediation of high indoor radon concentration:
    • will be used for purposes other than radon extraction,
    • will not be installed, which could lead to the installation of connections in the future being very difficult or costly, and
    • will not be adequately labelled, which could lead to the connections accidentally being opened or used for other purposes.

This is to limit the probability that radon cannot be extracted from all spaces between the air barrier and the ground, which could lead to high concentrations of radon inside buildings, which could lead to negative effects on the air quality of indoor spaces, which could lead to harm to persons.

Intent 2:

[Subclause (c)(ii)] To limit the probability that components of a future system for the remediation of high indoor radon concentration can bypass the air barrier system or that airtight seals will be removed, which could lead to the infiltration of soil gas, which could lead to negative effects on the air quality of indoor spaces, which could lead to harm to persons.