This information has been archived because it is outdated and no longer relevant.
Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.20.9.5.(2) | Application | Intent |
OS2 | OP2 | OH1 | OS1 |
Objective | OS2 Structural Safety |
Attribution | |
Application | Application 1: Fastening of strap ties to wood framing members, for
masonry veneer 75 mm or more in thickness and resting on a bearing
support, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9]:
Exceptions:
except as stated in Sentence 9.20.1.1.(2), which applies to buildings other than described above, or where the masonry
is designed for specified loads on the basis of ultimate and serviceability
limit states.
|
Top of Page | |
Intent | Intent 1: To limit the probability of:
This is to limit the probability of the excessive
flexing of masonry veneer, which could lead to cracking or buckling.
This is to limit the probability of compromised structural integrity,
which could lead to:
This is to limit the probability of harm to persons.
|
Top of Page |