Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.1.5.5.(1)
++
Application
Application 1: 
Thermal barrier protection for interior surfaces of exterior non-loadbearing wall assemblies that include combustible components, in buildings described in Sentence 1.3.3.2.(1) of Division A that are required to be of noncombustible construction, and where:
  • the building is not more than 3 storeys in building height, or is sprinklered throughout, and
  • the wall assembly satisfies the criteria of Sentences 3.1.5.5.(2) and (3) when subjected to testing in conformance with CAN/ULC-S134, “Standard Method of Fire Test of Exterior Wall Assemblies.”
Exceptions: 
except for an exposing building face required to conform to Sentence 3.2.3.7.(1) or Sentence 3.2.3.7.(4).
Application 2: 
This also applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9] required to be of noncombustible construction, as stated in Sentence 9.10.6.1.(1).
Top of Page
Intent
Intent 1: 
To expand the application of Sentence 3.1.5.12.(3).