This information has been archived because it is outdated and no longer relevant.
Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.1.5.5.(1) | Application | Intent |
+ | + |
Application | Application 1: Exterior non-loadbearing wall
assemblies that include combustible components,
in buildings described in Sentence 1.3.3.2.(1) of Division A that are required to be of noncombustible
construction, and where:
Exceptions:
except for an exposing building face required
to conform to Sentence 3.2.3.7.(1) or Sentence 3.2.3.7.(4).
Application 2: This also applies to buildings to
which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application
of Part 9] that are required to be of noncombustible
construction, as stated in Sentence 9.10.6.1.(1).
|
Top of Page | |
Intent | Intent 1: To exempt certain combustible materials from the application
of Sentence 3.1.5.1.(1) if certain conditions are met, on the basis
that the materials are deemed to insignificantly contribute to fire growth
and spread. Intent 2: To state the application of Sentences 3.1.5.5.(2) and (3).
|
Top of Page |