Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.1.10.2.(1)
OS1OP1+OP3
Application
Application 1: 
Upper portions of firewalls with a minimum fire-resistance rating of 2 h that separate upper storeys of a building or buildings within which the floor areas contain other than Group E or Group F, Division 1 or 2 major occupancies but having lower storeys that contain floor areas with Group E or Group F, Division 1 or 2 major occupancies.
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A, and to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) for application of Part 9] as stated in Sentence 9.10.11.3.(1).
Top of Page
Intent
Intent 1: 
To exempt certain upper portions of firewalls from the requirement to have a higher fire-resistance rating, on the basis that these upper portions of firewalls have the necessary fire-resistance rating for maintaining an appropriate level of safety.