Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.1.10.2.(2) | Application | Intent |
OS1 | OP1 | OP3 |
Objective | OP3 Protection of Adjacent Buildings from Fire |
Attribution | |
Application | Application 1: Minimum fire-resistance rating of
a firewall that separates storeys of
a building or buildings within
which all floor areas contain other than a Group
E or a Group F, Division 1 or 2 major occupancy.
|
Top of Page | |
Intent | Intent 1: To limit the probability that a firewall will have insufficient
fire-resistance, which could lead to the spread of fire from the building
to an adjacent building, which could lead to damage to the adjacent building.
Intent 2: To limit the probability that fire will spread from the
subject building to an adjacent building during the time needed for emergency
responders to carry out their duties, which could lead to damage to the adjacent
building. |