Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.1.10.2.(2)
OS1OP1OP3
ObjectiveOS1 Fire Safety
Attribution
Application
Application 1: 
Minimum fire-resistance rating of a firewall that separates storeys of a building or buildings within which all floor areas contain other than a Group E or a Group F, Division 1 or 2 major occupancy.
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A, and to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9] as stated in Sentence 9.10.11.3.(1).
Top of Page
Intent
Intent 1: 
To limit the probability that a firewall will have insufficient fire-resistance, which could lead to the spread of fire from one building to another, which could lead to to harm to persons in the building not originally involved in the fire.
Intent 2: 
To limit the probability that fire will spread from one building to another during the time needed for emergency responders to carry out their duties, which could lead to harm to persons in the building not originally involved in the fire.