Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.1.10.7.(2) | Application | Intent |
OS1 | OP1 | OP3 |
Objective | OP1 Fire Protection of the Building |
Attribution | |
Application | Application 1: Combustible projections
on the exterior of one building, including balconies,
platforms, canopies, eaves projections and stairs, that extend outward beyond
the end of the firewall, and are within 2.4
m of combustible projections and window
or door openings of the adjacent building.
|
Top of Page | |
Intent | Intent 1: To limit the probability that combustible material from
one building will be in close proximity to combustible material from another
building on the other side of a firewall, which could lead to the spread of
fire from an adjacent building to the building, which could lead to damage
to the building. |