Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.1.10.7.(2) | Application | Intent |
OS1 | OP1 | OP3 |
Objective | OS1 Fire Safety |
Attribution | |
Application | Application 1: Combustible projections
on the exterior of one building, including balconies,
platforms, canopies, eaves projections and stairs, that extend outward beyond
the end of the firewall, and are within 2.4
m of combustible projections and window
or door openings of the adjacent building.
|
Top of Page | |
Intent | Intent 1: To limit the probability that combustible material from
one building will be in close proximity to combustible material from another
building on the other side of the firewall, which could lead to the spread
of fire from one building to another, which could lead to harm to persons
in the building not originally involved in the fire. |
Top of Page |