This information has been archived because it is outdated and no longer relevant.
Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.1.14.1.(2) | Application | Intent |
OS1 | OP1 |
Objective | OP1 Fire Protection of the Building |
Attribution | |
Application | Application 1: Supports for fire-retardant
treated wood roof systems used to comply with the requirements of Subsection 3.2.2., in buildings described
in Sentence 1.3.3.2.(1) of Division A. The sentences
in Subsection 3.2.2. that relate to this provision are: 3.2.2.25.(2), 3.2.2.32.(2),3.2.2.53.(2), 3.2.2.59.(2), 3.2.2.69.(2) and 3.2.2.76.(2).
|
Top of Page | |
Intent | Intent 1: To limit the probability that inappropriate material will
be used for roof deck supports, which could lead to their involvement in the
growth and spread of fire, which could lead to the collapse of the supports,
which could lead to the collapse of the roof deck assembly, which could lead
to damage to the building. |
Top of Page |