Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.1.14.1.(2) | Application | Intent |
OS1 | OP1 |
Objective | OS1 Fire Safety |
Attribution | |
Application | Application 1: Supports for fire-retardant
treated wood roof systems used to comply with the requirements of Subsection 3.2.2., in buildings described
in Sentence 1.3.3.2.(1) of Division A. The sentences
in Subsection 3.2.2. that relate to this provision are: 3.2.2.25.(2), 3.2.2.32.(2), 3.2.2.53.(2), 3.2.2.59.(2), 3.2.2.69.(2) and 3.2.2.76.(2).
|
Top of Page | |
Intent | Intent 1: To limit the probability that inappropriate material will
be used for roof deck supports, which could lead to their involvement in fire
growth and spread, which could lead to the weakening and collapse of the supports,
which could lead to the collapse of the roof deck assembly, which could lead
to harm to persons, including emergency responders. Intent 2: To limit the probability that inappropriate material will
be used for roof deck supports, which could lead to their involvement in fire
growth and spread, which could lead to the spread of fire to occupied parts
of the building, which could lead to harm to persons. |